Hoffer Flow Control introduces liquid flow logger. Integrates 3 inputs into 1 display.




The Hoffer TriFlo 9500 System provides both system integrators and operators with the most flexible measurement solutions for produced water flow and hydrocarbon condensate flow measurement.

The TriFlo 9500 however, goes one step further and provides the capability to integrate up to three flow meter inputs into a single device rather than three separate displays
 
  • Complete interchangeability of components between three different sizes of flow meters (1”, 1½“ and 2”) Simple design of the meters reduces both parts costs and field servicing time.
  • System accuracy of ±1% or better.
  • Displays rate and total simultaneously.
  • Easy to read LCD display with operating temperature from -40° to +60°C.
  • Up to 16 point linearization.
  • Optional three turbine pulse inputs offers cost, space and weight savings.
  • RS-485 modbus protocol and SD card download for easy data retrieval.
  • Interface software available at no charge. 
    Data Sheet

    Wednesday, September 23, 2009

    High Voltage Switchgear and Sulfur Hexafluoride







    Background


    Moisture in Sulfur Hexafluoride (SF6) an insulating gas can cause rapid and severe deterioration of high-voltage switchgear.

    During electrical power distribution at transmission voltages (ranging typically from 100 to 400 kV), power switching or load current interruption is a major problem as a result of arcing between the two contact points. The insulation properties of SF6, used to pressurize such switchgear enclosures, effectively control arc formation. However, the entry of moisture over time results in electrical discharge, causing the SF6 to decompose into byproducts, such as hydrolysable fluorides.

    These fluorides are good dielectrics and their presence does not impair the operational efficiency of the respective equipment. However, this only applies when the moisture content of the gas or its enclosure is low. In the presence of water vapor, the by-products include the highly corrosive HF, which accelerates switch contact corrosion to the point of physical breakdown. The aggressive nature of HF means that the damage may spread to the surrounding areas of the switchgear enclosure causing further damage. The moisture content of the gas must be maintained to a minimum to avoid the formation of this acid.

    It is also important to maintain low moisture levels, to avoid condensation with the potential for leakage current across the surface of insulating parts.

    Measurement Technique

    Moisture measurements are important at the following stages:
    • Checking the moisture content of new SF6 in cylinders by industrial gas producers prior to supply and immediately prior to use by the switchgear manufacturer or transmission company. SF6 cylinders appear to be particularly susceptible to moisture ingress in storage. SF6 in good condition should have a moisture content of <10 ppmV equivalent to dew point <-75°F dew point (at atmospheric pressure).
    • Dry gas purging of new switchgear enclosures during the final stage of manufacturer or following internal maintenance work prior to pressuring and sealing with SF6. Most commonly, high purity nitrogen or another inert gas from cylinders is used, by repeated pressurization and venting to atmosphere, until the moisture content within the enclosure has been reduced to <10ppmV equivalent to dew point <-75 °F dew point (at atmospheric pressure).
    • In service checks and continuous monitoring to ensure that moisture content in the SF6 is maintained below the critical levelof 100 ppmV, -40 °C dew point (at atmospheric pressure). 
    For all of these applications, use the Hygroport Portable Hygrometer. This portable, easy to use instrument responds rapidly and displays moisture content in a variety of engineering units, including ppmW for SF6,. Up to 320,000 measurement points can be stored with its built-in data logging facility and then quickly downloaded to a PC with a bluetooth wireless connection.

    For more information on Kahn visit our website

    Monday, September 14, 2009

    Data Logging for Diesel Engine Emissions Control

    Introduction
    Recent local, state and federal mandates have required the reduction of harmful emissions, both particulate and NOx, from diesel engines used in off road equipment, generators, buses and construction equipment. A variety of control technologies exists, but each is best suited for a specific engine use map and a key part of retrofitting this equipment is collecting data to determining this use map. After the emissions reduction equipment has been installed, it’s also necessary to monitor engine performance to make sure that the equipment has not adversely effected the operation on the engine. This paper will review the data logging requirements for this application, the sensors required and sensor mounting considerations and data logger requirements.

    Overview
    Addition of new emission requirements for diesel engines has necessitated need to monitor and record engine operating information including:
    1. Exhaust back pressure
    2. Exhaust gas temperature
    3. Engine RPM
    4. Engine load, throttle position, fuel consumption and other operating data

    Why do these parameters need to be monitored? There are 2 main reasons why it’s important to monitor these parameters. First, the engine operating conditions to determine which of the available emissions reduction strategies is the best fit. The optimal method depends on typical engine load and duty cycle, exhaust gas temperature and other operating parameters that are specific to the way the engine is being used.

    Once the equipment is installed, it’s important to collect data to ensure that the control equipment does not cause the engine to operate outside its design limits. For example, a clogged particulate filter can lead to abnormal exhaust back pressure which will reduce engine performance and can lead to overheating and damage.

    Equipment Required
    A typical monitoring system will include at a minimum a data logger, a thermocouple to monitor engine exhaust gas temperature, a pressure sensor to monitor exhaust gas back pressure and an engine RPM sensor. In some cases, a second pressure sensor will be added to monitor the differential pressure across a particulate filter. Engines fitted with a turbocharger or supercharger can be fitted with a boost pressure sensor. Modern engines with an electronic control unit (ECU) often have a CANbus interface available that allows for the collection of many engine operating parameters. Finally, some systems that are used in mobile applications require the collection of GPS information to track location information to determine what specific pollution control district the engine is being used in.

    Data logger
    The typical application will require 2-5 analog input channels for the different temperature and pressure sensors. If engine RPM will be used using one of the sensors described below, a counter or frequency input will be required for pick-up. Most applications for the loggers will be in-vehicle so operation from 12 to 24 VDC vehicle power is advantageous. Equipment vendors often ask for digital outputs for alarms, visible or audible, to warn the operator if the engine is operating outside of its design limits.

    Obviously, some interface for a PC has to available both to configure the data logger and to download recorded data. Traditionally, serial (RS-232) interfaces were common, but many new computers do not include serial ports and today USB is the most common communication interface. Ethernet is also popular communication method although configuring network addresses is a little more involved than USB “plug and play” The inclusion of an interface for a removable USB stick or Compact Flash card provides a very convenient way to unload data when it’s not practical to hook up a PC to the logger in the field.

    Typically, it’s required that the logger be able to collect and store data locally for 1-4 weeks of data. For an application where the logger is collecting 3 inputs (exhaust temp, exhaust back pressure and RPM) at 1 second intervals for 8 hours a day, this means that the logger must be able to store 500,000 to 2 million points.

    It’s often very desirable to remotely monitor the equipment operations. A variety of cellular and satellite modems are available that provide the ability to remotely connect to the system and view real-time and/or historical data. In this case, the logger must incorporate a communications port to interface to modem with RS-232 being the most commonly used interface.

    Exhaust Gas Back Pressure Sensor
     Exhaust gas back pressure is normally in the range of 0-2 PSI. While it’s possible to use a sensor with a 0-50 PSI range, it may not produce the required accuracy since it will be operating at a fraction of its full scale range. Typically we recommend 0 – 5 or even 0-2.5 PSI for the best accuracy. The small incremental expense is well worth the improved accuracy.

    There are 2 key points that need to be stressed when mounting the sensor. First, the sensor must be protected from direct exposure to the hot exhaust gas. These pressure sensors typically employ a thin diaphragm with a piezoresistive bridge to measure its deflection. Because of this, the sensor output will be temperature dependent and direct exposure to the hot gases will cause unwanted measurement errors. Fortunately, the solution is simple: simply mount sensor on length of small diameter tubing to provide a buffer to protect it from exhaust gas stream. We typically recommend a piece of  ¼” O.D. tubing a minimum of 18” long.

     Second, the pressure sensor should be mounted with outlet facing down to prevent the accumulation of contamination in the sensor. The exhaust stream can contain moisture which can condense and when combined with the chemicals in the exhaust gases lead to the build up of acids that can damage the sensing diaphragm.

    Exhaust Gas Temperature Sensor
    By far the most common exhaust gas temperature sensor is the type K thermocouple. These are suitable for temperatures up to 1000? C. We recommend using probes with a stainless steel sheath (avoid inconel or other materials as it may react with exhaust gas).  By using a probe with a ¼” O.D., a standard swage type fitting can be threaded into a tapped hole in the exhaust pipe to provide a leak tight installation. To reduce interference from other signals, use an ungrounded probe to isolate the thermocouple junction. Also, because of small signal voltage level, use shielded cable with ONE end connected to chassis ground to reduce the effects of EMI and RFI interference.

    RPM sensor
    We have identified 3 strategies for measuring engine RPM including
    1.      Reflective or interrupting optical sensors
    2.      proximity sensors
    3.      frequency transducers that monitor the alternator output
    The choice of which method to use is often driven by cost and installation considerations. The last method, using the residual ripple in the alternator output which is proportional to RPM is very easy to install (simply connect a wire to the alternator output) but there is additional cost for the signal conditioning electronics and there is some calibration that is required since this signal will be some harmonic of the engine speed. Reflectance or proximity sensors are very easy to use since they can provide the RPM directly as a pulse output of the correct frequency but it is often more difficult to locate and mount the hardware.

    CAN Interface
    The typical vehicle or engine ECU can provide a wealth of performance information via the vehicle bus. Heavy duty and off road engines generally have a J1939 CAN bus interface that can be configured to read RPM, engine load, throttle position and dozens of other parameters. These are often very useful in selecting the optimal emissions reduction strategy for a particular application. To interface to the data logger, a CANbus to serial gateway provides an easy to use solution. The gateway can be configured to capture standard CAN messages, extract the parameters of interest and format them off-loading much of the work from the logger. Often the hardest task is coming up with an interface cable as there seem to be a variety of “standard” CAN connectors including 6 and 9 pin Deutch, OBD-II and proprietary. We often find that the easiest way to make a pigtail and splice directly into the connector.

    GPS
    To provide GPS tracking information, an off-the-shelf GPS sensor such as a Garmin GPS-18 with a serial interface can be easily integrated into the system. Using the standard NEMA output format allows for turn-key generation of logger configuration commands to read latitude, longitude, altitude, heading, and speed. When mounting the GPS receiver, it’s important to note that it must have a relatively unobstructed view of the sky which requires that it not be mounted in a metal enclosure or metal compartment that shields it. When used in conjunction with a tool such as Google Earth, GPS data combined with other sensor data can provide a very intuitive map of engine operating parameters vs. location.

    Measurement Program Description
    The data logging program is straight forward. Typically the data logger is set to record temperature, pressure, RPM and possibly CAN parameters at 1-10 second intervals while the engine is running. Several methods are employed to start and stop logging. Obviously, the logger could simply be powered off a source that is switched on and off by the ignition, but switching off the logger in the middle of a sample can cause data corruption. It’s much better to use an external trigger to enable and disable logging. One way is to set-up the logger to continuously monitor a parameter that indicates the engine is running, either the exhaust gas temperature, vehicle power line or RPM, and then enable or disable the main sampling schedule when the engine is on. For example, the program can monitor the exhaust gas temperature once a minute and only log while the temperature is above 200? C, a value that indicates the engine is running. Another technique is to use on of the digital trigger inputs connected to the vehicle switched power through appropriate signal conditioning to enable or disable logging. Either of these 2 methods allows the logger to only record useful data and still shut down gracefully when the vehicle is turned off.

    Some customers also require alarms, either audible, visual or both , to indicate if one of the key parameters, either exhaust gas temperature or back pressure, is outside of preset limits. As part of the normal measurement schedule, the logger can compare measured values against programmed limits and using a digital output to actuate the alarm. The loggers also has a delay capability so that the alarm condition must be true for some period of time before the alarm is activated to prevent false triggers in cases where the condition is true for only an instant.

    Data Retrieval
    In most applications, the logger will be allowed to collect data for 1-4 weeks and then the stored data will be downloaded to a PC for analysis. Several different methods are employed to retrieve stored data including direct connection to the data logger, transfer to removable media and remote communication via a modem.

    As describe above, directly connecting a PC to the logger and using the vendor supplied tools to unload data maybe the easiest way to retrieve the stored information, but it is not always the most convenient. In some cases the logger is installed in a vehicle that may be in a remote location, or it may be impractical to pull the equipment out of service for a period of time to unload the data.

    Removable storage devices provide an alternative to downloading the data to a PC. The logger can be configured to store all of the information directly on a USB or compact flash card. These can then be periodically swapped out (in some cases by the equipment operator) and then taken back to the office where the data can be off-loaded to a computer.

    The other alternative is to use a cellular modem to provide remote access to the logger. Currently there are 2 popular cellular technologies, CDMA and GSM/GPRS. The CDMA is an older technology that offers the best coverage area at the expense of slower data transfer rates. GSM/GPRS cellular coverage is a bit more limited, but is available in most metropolitan areas. In either case, we found that using data plans with a fixed IP address provides for the easiest set-up and most robust communication. In this case, connection to the logger becomes as easy as connecting to it as if it was on your desktop.

    Data Analysis
    One factor that is often not considered is what to do with the data once it has been collected and download to the PC. It’s quite easy for the logger to generate data files that swamp programs such as MS Excel which has a 65,000 row limit. Typically, software tools supplied by the data logger vendors allow larger data sets, but are limited in their analysis features.

    We have found several alternative approaches. Probably the best is to reduce the amount of data that is collected. As simple as it seems, this is often overlooked. Typically, the users are not interested in individual data samples but rather summarized data such as the average value, minimum and maximum values, and other statistical information that describes the data. In this case, using a data logger that can do the statistical reduction on the raw samples can dramatically reduce the amount of data that must be stores and transferred.

    If the user really wants to look at all of the raw data, the other alternative is to use more powerful analysis tools such as Flexpro or Origin. To facilitate transferring the data to these programs, it’s essential that the data logger software be able to output data files in and open format such as .CSV.

    Example System
    We have delivered several dozen systems for this application that meet the requirements that are discussed above. These systems incorporate a DT80 data logger as the heart of the system. This logger has 5 analog input channels that can accept up to 15 sensor inputs depending on sensor type. The systems were outfitted with a type K thermocouple probe and 1 or 2 pressure sensors. To monitor CANbus parameters, a CANgate serial to CAN converter was connected to the serial sensor input of the data logger. The CANgate also accepts GPS data from a standard Garmin GPS-18 receiver. Additional analog, digital and counter inputs on the data logger provide the flexibility to add other sensors and trigger inputs. The data logger, CANgate and cellular modem were packaged in a NEMA enclosure to provide environmental protection. These systems have been used in a wide variety of vehicles including school buses, transit buses, cranes, and snow-cats.

    Summary
    The collection of diesel engine operating data is currently a very active application driven by various government mandates to reduce harmful emissions. As is typical of most data logging applications, there are a number of considerations in assembling a system to collect this data including
    1.      Defining which parameters must be monitored
    2.      Data logger selection
    3.      Sensor selection
    4.      Sensor mounting and electrical connections
    5.      Data logger programming
    6.      Alarm indication if required
    7.      Data retrieval
    8.      Data analysis
    This paper has presented some of the knowledge gained in each of these areas from multiple installations at different customer sites across the US.